Product Description
Uniflair Direct expansion air-cooled unit downflow with EC backward curved fans and brushless VSD compressors
Uniflair Med/Large Room Cooling Features & Benefits
AVAILABILITY
- Redundant Components
Single points of failure in the system have redundant components to maintain availability and reliability.
- Electronic expansion valve
Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
- Multi-functional Microprocessor Controller
Allows the units to restart after a power failure without intervention; Allows for room level redundancy with up to ten units operating in a group; User friendly navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System protocols.
- Active response control
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
- Direct drive motors
Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
ENERGY MANAGEMENT
- Building Management Systems
Units are designed to work with the most common BMS systems including BACnet and Modbus.
- Network interface
Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.
- Automatic Floor Pressurization System
Ensures stable airflow pressurization under floor regardless of changes made above the floor
- Local area network: Creates a shared control between all the available resources for maximum energy efficiency and controlled management of the group during emergency situations
SERVICEABILTY
- Operational Service: Allows critical components to be maintained/replaced while the system is in operation.
- Easy service access: Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
- Service monitoring: All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.
TOTAL COST OF OWNERSHIP
- Optimized management
Connection between the Computer Room Air Conditioners and the chillers guarantees energy efficiency, based on real instantaneous load conditions (optional)
- Modular strategy
Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expediture and provides deferred investment throughout the life of the facility.
- Electronically Commutated Fans
Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.
Jerald Hearnsberger – :
Youre so cool! I dont suppose Ive read something like this before. So nice to search out anyone with some original thoughts on this subject. realy thanks for beginning this up. this website is something that is wanted on the web, somebody with slightly originality. helpful job for bringing something new to the internet!
https://www.droversointeru.com
Latocoaws – :
Acceptance testing for nuclear medicine instrumentation how to take priligy
Latocoaws – :
Risk of Spread of Focal Dystonia The Pressure of Air Travel Headaches on the Plane Acupuncture Is There a Point in Patients with Migraines priligy for pe The administration of NSAIDs inhibits prostaglandin synthesis, reduces renal perfusion, and may cause a significant reduction in glomerular filtration rate
Latocoaws – :
Another attempt to test in vivo the existence of a G4 was performed by microinjecting zebrafish embryos with a small G4 stabilizing ligand furan based cyclic homo oligopeptide and assessing the effect upon embryonic development buy priligy dapoxetine online Ex Clofibrate, an antilipidemic agent causes a proliferation of peroxisomes in rat liver and an associated increase in tumor incidence without any evidence of covalent binding of radio labeled compounds; such compounds are detected as mutagenic in Ame s assay
mandala lebensbaum – :
It’s laborious to seek out knowledgeable individuals on this topic, however you sound like you understand what you’re talking about! Thanks
https://diamondpaintingmarkt.de/products/rond-dp-lampje-mandala-levensboom
berita informasi terbaru – :
I would like to thnkx for the efforts you’ve put in writing this website. I am hoping the same high-grade web site post from you in the upcoming as well. In fact your creative writing abilities has encouraged me to get my own web site now. Actually the blogging is spreading its wings rapidly. Your write up is a great example of it.
https://beritamasadepan.com/